Agilent IntuiLink for PSG/ESG Signal Generators

Software 1.0 through 4.2 Release Descriptions


Software 4.2 Released June 26, 2003

Software 4.0 Released September 13, 2002

Software 3.0 Released October 1, 2002

Software 2.0 Released June 1, 2002

Software 1.0 Released February 1, 2001

 

Related Information

Upgrading PSG/ESG Firmware
PSG/ESG Download Assistant software for MATLAB®
Agilent IO Libraries
Provide Feedback About Our Signal Generators

 


Software 4.2

Software version 4.2 is a revised version of IntuiLink for PSG/ESG Signal Generators. 

Software 4.2 Enhancements

·        Added support for Options 601 and 602 internal baseband generators with digital bus capability for the E4438C ESG.

·        Added support for Option 602 internal baseband generator with digital bus capability for the E8267C PSG. 

·        Added the ability to upload encrypted waveforms from the signal generator.  This gives the user the ability to transfer waveforms from a signal generator  to a computer and download this waveform to another signal generator. 

o       The E4438C ESG requires firmware C.03.30 or later to use this functionality.

o       The E8267C PSG requires firmware C.03.31 or later to use this functionality. 

Software 4.2 Issues Resolved

·         The “.com” in the TCP/IP address string is no longer misinterpreted.

Software 4.2 Hardware and Firmware Compatibility

This software is compatible with signal generators with the following hardware and firmware options:

Screen captures and save/restore instrument states from IntuiLink are supported on all the models listed below.  

Waveform downloads are supported on the models listed below

Model Number

Supported Instrument Interface 

Required Version of Agilent IO Libraries

E8267C

 GPIB  

10BaseT LAN

L.02.00 or later

E4438C

 GPIB

10BaseT LAN

L.02.00 or later

E443xB; where x=0 through 7

GPIB (required for waveform downloads)   

RS-232 (does not support waveform downloads)

L.02.00 or later

 

Waveform downloads are NOT supported on the following models:

Model Number

Supported Instrument Interface 

Required Version of Agilent IO Libraries

E8257C

GPIB

10BaseT LAN

L.02.00 or later

E8247C

GPIB

10BaseT LAN

L.02.00 or later

E8251A and E8254A

GPIB

10BaseT LAN

L.02.00 or later

E8241A and E8244A

GPIB

10BaseT LAN

L.02.00 or later

E4400B and  E442xB; where x=0 through 6

GPIB (required for waveform downloads)

RS-232 (does not support waveform downloads)

L.02.00 or later

 

Back to top of page


Software 4.0

Software 4.0 Enhancements

·         Added support for  the following model numbers:

o        E8247C

o        E8257C

o        E8267C

·         From the Download Waveform  menu, renamed the file Type from "E443xB internal values"  to "14-bit internal values", and "E4438C internal values" to "16-bit internal values".  The "14-bit internal values" waveform type should be selected for binary waveforms formatted for the E443xB and the "16-bit internal values" waveform type should be selected  for binary waveforms formatted for the E4438C and the E8267C.

Software 4.0 Issues Resolved

·         Updated software to prevent "Signatures have expired" warning message from appearing every time an Office application was launched.

·         Conversion from 14-bit internal values to 16-bit internal values modified so that the UNLEVEL is no longer displayed on the ESG during this operation.

Software 4.0 Hardware and Firmware Compatibility

This software is compatible with signal generators with the following hardware and firmware options:

Screen captures and save/restore instrument states from IntuiLink are supported on all the models listed below.  

Waveform downloads are supported on the models listed below

Model Number

Supported Instrument Interface 

Required Version of Agilent IO Libraries

E8267C

 GPIB  

10BaseT LAN

L.02.00 or later

E4438C

 GPIB

10BaseT LAN

L.02.00 or later

E443xB; where x=0 through 7

GPIB (required for waveform downloads)   

RS-232 (does not support waveform downloads)

L.02.00 or later

 

Waveform downloads are NOT supported on the following models:

Model Number

Supported Instrument Interface 

Required Version of Agilent IO Libraries

E8257C

GPIB

10BaseT LAN

L.02.00 or later

E8247C

GPIB

10BaseT LAN

L.02.00 or later

E8251A and E8254A

GPIB

10BaseT LAN

L.02.00 or later

E8241A and E8244A

GPIB

10BaseT LAN

L.02.00 or later

E4400B and  E442xB; where x=0 through 6

GPIB (required for waveform downloads)

RS-232 (does not support waveform downloads)

L.02.00 or later

 

Back to top of page


Software 3.0

Software 3.0 Enhancements

Software 3.0 Hardware and Firmware Compatibility

This software is compatible with signal generators with the following hardware and firmware options:

Screen captures and save/restore instrument states from IntuiLink are supported on all the models listed below. 

Waveform downloads are supported on the models listed below:

Model Number

Supported Instrument Interface

Required Version of Agilent IO Libraries

E4438C

 GPIB  

10BaseT LAN  

J.01.02 or later

K.01.00 or later

E443xB; where x=0 through 7

GPIB (required for waveform downloads)

RS-232 (does not support waveform downloads)

J.01.02 or later

 

Waveform downloads are NOT supported on the models listed below:

Model Number

Supported Instrument Interface

Required Version of Agilent IO Libraries

E8251A and E8254A

GPIB

10BaseT LAN

J.01.02 or later

K.01.00 or later

E8241A and E8244A

 GPIB

10BaseT LAN

J.01.02 or later

K.01.00 or later

E4400B and  E442xB; where x=0 through 6

GPIB (recommended)

RS-232

J.01.02 or later

 

 

 

 

 

 

 

Back to top of page


Software 2.0

Software 2.0 Enhancements

Software 2.0 Hardware and Firmware Compatibility

This software is compatible with signal generators with the following hardware and firmware options:

Screen captures and save/restore instrument states from IntuiLink are supported on all the models listed below.

Waveform downloads are supported on the models listed below:

Model Number

Supported Instrument Interface

Required Version of Agilent IO Libraries

E443xB; where x=0 through 7

GPIB (required for waveform downloads)

RS-232 port (does not support waveform downloads) 

 J.01.02 or later

 

Waveform downloads are NOT supported on the models listed below:

Model Number

Supported Instrument Interface 

Required Version of Agilent IO Libraries

E8251A and E8254A

GPIB

10BaseT LAN

J.01.02 or later

K.01.00 or later

E8241A and E8244A

 GPIB

10BaseT LAN

J.01.02 or later

K.01.00 or later

E4400Band  E442xB; where x=0 through 6

GPIB (recommended)

RS-232

J.01.02 or later

 

 

 

 

 

 

Back to top of page


Software 1.0

Software 1.0 Hardware and Firmware Compatibility

This software is compatible with signal generators with the following hardware and firmware options:

Screen captures and save/restore instrument states from IntuiLink are supported on all the models listed below. 

Waveform downloads are supported on the models listed below:

Model Number

Supported Instrument Interface 

Required Version of Agilent IO Libraries

E443xB; where x=0 through 7

GPIB (required for waveform downloads)

RS-232 port (does not support waveform downloads)

J.01.02 or later

 

Waveform downloads are NOT supported on the models listed below:

Model Number

Supported Instrument Interface 

Required Version of Agilent IO Libraries

E4400B and  E442xB; where x=0 through 6

GPIB (recommended)   

RS-232

J.01.02 or later

Back to top of page


Microsoft is a U.S. registered trademark of Microsoft Corporation.
MATLAB is a U.S. registered trademark of The Math Works, Inc.

© Copyright 2002, 2003 Agilent Technologies, Inc. All rights reserved.
Other product and company names herein may be the trademarks of their respective owners.